Operation steps for installation and removal of low price screw cooler for CFB boilers


Release time:

Jun 18,2022

Now many customers will inspect the low price screw cooler for CFB boilers by themselves, but during the inspection process, they must be completed according to the installation and disassembly steps, otherwise it will have a great impact on its performance. The following is the specific operation method, I hope you able to comply.

Now many customers will inspect the low price screw cooler for CFB boilers by themselves, but during the inspection process, they must be completed according to the installation and disassembly steps, otherwise it will have a great impact on its performance. The following is the specific operation method, I hope you able to comply.
1. Before disassembling the low price screw cooler for CFB boilers, the oil and water valve should be closed to discharge the internal liquid.
2. When disassembling, you can consider disassembling the return water cover and the water distribution cover first.
3. After disassembly, check whether the gasket is damaged and whether the pipeline of low price screw cooler for CFB boilers is in good condition, and deal with it accordingly.

low price screw cooler for CFB boilers
4. If the cooling tube of the low price screw cooler for CFB boilers is damaged and needs to be pulled out and replaced, it should be pulled out from the direction of the fixed tube sheet. When encountering a large low price screw cooler for CFB boilers, we can turn the fixed tube sheet downward and lift the outer tube shell to expose the tube bundle, which is convenient for pulling out.
5. Before installation, check the integrity of the gasket to ensure that it is not damaged.
6. Install in the reverse direction of disassembly.
7. After installation, test the air tightness of the low price screw cooler for CFB boilers to ensure that there is no leakage.